12x Digital I/O via SM fiber optic converter, IOL3200
The fiber optic system IOL3200 transmits digital signals (e.g., contact closures, control-signals) via singlemode (SM) fiber optics.
Using adressed subscribers, the fiber optic system is able to transmit up to 12 digital signals (12–24 VDC) within a point-to-point structure.
The interconnection of an input/pass system allows the transmission of additional digital data. You can choose if you want to have an electric disjunction (OR) of electrically and optically received data or if the electric data shall overwrite the optical data. The devices are available for line or ring structures as one fiber solutions.
LEDs and potential-free contacts of a fault detector relay are able to signal defective states.
Product variants
Article Number | Product Name | |
---|---|---|
032001331 + 032002331 + | IOL-3200/TX+RX-12D-13-SM-ST Transmitter+Receiver/24V/TX-RX/SM/ST | + Request quote |
IOL3200, 12 digital I/O, Transmitter + Receiver, ST, singlemode fiber optic | ||
032001323 + 032002323 + | IOL-3200/TX+RX-12D-13-SM-SC Transmitter+Receiver/24V/TX-RX/SM/SC | + Request quote |
IOL3200, 12 digital I/O, Transmitter + Receiver, SC, singlemode fiber optic | ||
032001335 + 032002335 + | IOL-3200/TX+RX-12D-13-SM-E2 Transmitter+Receiver/24V/TX-RX/SM/E2 | + Request quote |
IOL3200, 12 digital I/O, Transmitter + Receiver, E2000, singlemode fiber optic |
Description
The fiber optic system IOL3200 transmits digital signals (e.g., contact closures, control-signals) via fiber optics.
Using adressed subscribers, the fiber optic system is able to transmit up to 12 digital signals (12–24 VDC) within a point-to-point structure.
The interconnection of an input/pass system allows the transmission of additional digital data. You can choose if you want to have an electric disjunction (OR) of electrically and optically received data or if the electric data shall overwrite the optical data. The devices are available for line or ring structures as one fiber solutions.
LEDs and potential-free contacts of a fault detector relay are able to signal defective states.
Specifications
- FO-connector:
- ST, SC or E2000
- Fiber type:
- Singlemode 9/125μm
- Optical budget:
- 16 dB
- FO range:
- 30 km, others up to 100 km on request (0,3 dB/km)
- Wavelength:
- 1310 nm
- Signal input:
- 12-24VDC/5mA
- Signal output:
- 30 VDC (1A) / 60 VDC (0,2 A)
- Cable lenght:
- 1m
- Connector:
- 16-pole Screw-Terminal
- Status-LEDs:
- Power supply (green) / Failure (red) / Data receive (green) / Status (red) / FiberView (red, yellow, green)
- Power consumption:
- 5 Watts, 200 mA (24 V)
- Galvanic isolation:
- 500 VDC
- Operating temperature:
- –40 °C – +70 °C (Multimode and Singlemode with ST or SC) / –20 °C – +55 °C (all others)
- EMC:
- EN61000-6-2/EN55022 Class B + A1 + A2
- Weight:
- 570 g
- Dimensions:
- 60 x 100 x 113 mm (60 x 120 x 113 mm incl. connector)
- Housing:
- Stainless steel, powder coated