010008281-L-V3

CAN-bus to Single mode converter, Redundant, DL-CAN-R

The special multifunctional fiber optic system DL CAN-R also allows the construction of optical ring structures. The DL-CAN-R modules connect CAN field bus networks (e.g. CAN, CANopen, DeviceNet) via single mode fiber optics. The special multifunctional fiber optic system DL CAN-R also allows the construction of optical ring structures. 

Remark:
The 0100075xx series has been replaced by the 0100084xx series and is not compatible. If you want to expand an existing installation with 0100075xx modules, please contact support.

Read more

Product variants

Article Number Product Name
010008281-L-V3 + DL-CAN-R/13-SM-ST-L CAN/SM/Ring + Request quote
CAN-bus to Single mode converter for a redundant ring network, ST adapter.
010008283-L-V3 + DL-CAN-R/13-SM-SC-L CAN/SM/Ring + Request quote
CAN-bus to Single mode converter for a redundant ring network, SC adapter.
010008283-BIDI-L-V3 + DL-CANR/2x13-SM-SC-BIDI-L CAN/SM/Ring + Request quote
CAN-bus to Single mode converter for a redundant ring network, SC-BIDI adapter.
010008285-L-V3 + DL-CANR/2x13-SM-E2000 CAN/SM/Ring + Request quote
CAN-bus to Single mode converter for a redundant ring network, E2000 adapter.

Description

The DL CAN systems connect CAN field bus networks (e.g. CAN, CANopen, DeviceNet) via fiber optics. The special multifunctional fiber optic system DL CAN-R also allows the construction of optical ring structures.

LEDs and potential-free contacts of a fault detector relay are able to signal defective states.

Specifications

FO-connector:
ST, SC, E2000 or SC-BIDI
Fiber type:
Singlemode 9/125µm
Optical budget:
16 dB
FO range:
30 km, others up to 100 km on request (0,3 dB/km)
Wavelength:
1310 nm (1310/1550 nm for BIDI version)
Data rate:
10, 20, 22,2, 50, 100, 125, 250, 500, 800, 1000 KBaud Switchable: none or wave impedance (Rw + Rpd + Rpu)
Transmission type:
Half duplex
Indentifier:
11 Bit, 29 Bit or both
Terminating resistor:
Switchable: none or wave impedance (Rw + Rpd + Rpu)
CAN cable length:
Acc. to CAN Specification
CAN connector:
9-pole Sub-D female and 6-pole terminal
Status LEDs:
Power supply (green) / Failure (red) / Data receive (green) / Status (red) / FiberView (red, yellow, green)
Power supply:
12 to 30 VDC, other voltages on request
Power consumption:
5 Watts, 200 mA (24 V)
Galvanic isolation:
500 VDC (24 VDC <> CAN)
Operating temperature:
-40°C to +70°C (Multimode and Singlemode with ST or SC) / -20°C to +55°C (all others)
EMC:
EN61000-6-2/EN55022 Class B + A1 + A2
Weight:
570 g
Dimensions:
60 x 100 x 113 mm (60 x 120 x 113 mm incl. connector)
Housing:
Stainless steel, powder coated

Do you have a request?

Request type
Art. Nr. Product name Remove

You can add another variation to your request

Do you have a request?